Osmotically controlled system (ORDS- CT) -The OROS-CT can be used to target the drug locally to the colon for the treatment of disease or to achieve systemic absorption.-An orifice is drilled through the membrane next to the drug layer -Immediately after the OROS-CT is swallowed, the gelatin capsule containing the push-pull units dissolves -Because of its drug-impermeable enteric coating, each push-pull unit is preventedfrom absorbing water in the acidic aqueous environment of the stomach, and hence no drug is delivered.-As the unit enters the small intestine, the coating dissolves in this higher pH environment(pH >7), water enters the unit, causing the osmotic push compartment to swell and concomitantly creates a flowable gel in the drug compartment.