لخّصلي

خدمة تلخيص النصوص العربية أونلاين،قم بتلخيص نصوصك بضغطة واحدة من خلال هذه الخدمة

نتيجة التلخيص (45%)

Chemical and Autoclave Sterilization Methods Outlined in Annex III of the WHO Infection Control Guidelines for Transmissible Spongiform Encephalopathies

The three most stringent sterilization methods for heat-resistant instruments described in Annex III of the WHO guidelines are listed below; the methods are listed in order of more to less severe treatments.The article summarizing the findings of this experiment pdf icon[PDF - 211KB] by Brown et al. of the FDA was published in the Journal of Biomedical Materials Research (electronic version published October 2004).An experiment pdf icon[PDF - 88KB] conducted by Food and Drug Administration (FDA) investigators indicated that the use of appropriate containment pans and lids prevents escape of sodium hydroxide vapors that may cause damage to the autoclave (Brown and Merritt.[CDC NOTE: Sodium hypochlorite may be corrosive to some instruments.]

FDA investigators evaluated the effects to surgical instruments of the steps involved in the sterilization protocols listed above; some of the protocols they assessed subjected the instruments to harsher conditions than those prescribed above.[CDC NOTE: Sodium hypochlorite may be corrosive to some instruments.]

3- Immerse in 1N NaOH or sodium hypochlorite (20,000 ppm available chlorine) for 1 hour; remove and rinse in water, and then transfer to open pan and heat in a gravity displacement (121?C) or porous load (134?C) autoclave for 1 hour; clean; and subject to routine sterilization.


النص الأصلي

Chemical and Autoclave Sterilization Methods Outlined in Annex III of the WHO Infection Control Guidelines for Transmissible Spongiform Encephalopathies


The three most stringent sterilization methods for heat-resistant instruments described in Annex III of the WHO guidelines are listed below; the methods are listed in order of more to less severe treatments. Sodium hypochlorite may be corrosive to some instruments, such as gold-plated instruments. Before instruments are immersed in sodium hypochlorite, the instrument manufacturer should be consulted about the instrument’s tolerance of exposure to sodium hypochlorite. Instruments should be decontaminated by a combination of the chemical and recommended autoclaving methods before subjecting them to cleaning in a washer cycle and routine sterilization.


1- Immerse in a pan containing 1N sodium hydroxide (NaOH) and heat in a gravity displacement autoclave at 121°C for 30 min; clean; rinse in water; and subject to routine sterilization.
[CDC NOTE: The pan containing sodium hydroxide should be covered, and care should be taken to avoid sodium hydroxide spills in the autoclave. To avoid autoclave exposure to gaseous sodium hydroxide condensing on the lid of the container, the use of containers with a rim and lid designed for condensation to collect and drip back into the pan is recommended. Persons who use this procedure should be cautious in handling hot sodium hydroxide solution (post-autoclave) and in avoiding potential exposure to gaseous sodium hydroxide, exercise caution during all sterilization steps, and allow the autoclave, instruments, and solutions to cool down before removal. An experiment pdf icon[PDF – 88KB] conducted by Food and Drug Administration (FDA) investigators indicated that the use of appropriate containment pans and lids prevents escape of sodium hydroxide vapors that may cause damage to the autoclave (Brown and Merritt. Am J Infect Control 2003;31:257-260).]


2- Immerse in 1N NaOH or sodium hypochlorite (20,000 ppm available chlorine) for 1 hour; transfer instruments to water; heat in a gravity displacement autoclave at 121°C for 1 hour; clean; and subject to routine sterilization.
[CDC NOTE: Sodium hypochlorite may be corrosive to some instruments.]


3- Immerse in 1N NaOH or sodium hypochlorite (20,000 ppm available chlorine) for 1 hour; remove and rinse in water, and then transfer to open pan and heat in a gravity displacement (121°C) or porous load (134°C) autoclave for 1 hour; clean; and subject to routine sterilization.
[CDC NOTE: Sodium hypochlorite may be corrosive to some instruments.]


FDA investigators evaluated the effects to surgical instruments of the steps involved in the sterilization protocols listed above; some of the protocols they assessed subjected the instruments to harsher conditions than those prescribed above. Their findings indicate that much of the damage from autoclaving in sodium hydroxide was cosmetic and would not affect the performance or cleaning of the instruments. Soaking in sodium hydroxide had the least damaging effect on instruments, but immersion in sodium hypochlorite bleach caused severe damage to some instruments. The article summarizing the findings of this experiment pdf icon[PDF – 211KB] by Brown et al. of the FDA was published in the Journal of Biomedical Materials Research (electronic version published October 2004).


تلخيص النصوص العربية والإنجليزية أونلاين

تلخيص النصوص آلياً

تلخيص النصوص العربية والإنجليزية اليا باستخدام الخوارزميات الإحصائية وترتيب وأهمية الجمل في النص

تحميل التلخيص

يمكنك تحميل ناتج التلخيص بأكثر من صيغة متوفرة مثل PDF أو ملفات Word أو حتي نصوص عادية

رابط دائم

يمكنك مشاركة رابط التلخيص بسهولة حيث يحتفظ الموقع بالتلخيص لإمكانية الإطلاع عليه في أي وقت ومن أي جهاز ماعدا الملخصات الخاصة

مميزات أخري

نعمل علي العديد من الإضافات والمميزات لتسهيل عملية التلخيص وتحسينها


آخر التلخيصات

These studies a...

These studies are also prone to certain biases. For example, we wish to study the relation between d...

تتفاوت‎ ﺗﺟﺎرب ا...

تتفاوت‎ ﺗﺟﺎرب اﻟﻧﺳﺎء ﻟﻸﻟم أﺛﻧﺎء اﻟوﻻدة وﺗﻌﻘﯾداﺗﮭﺎ. ﺗم اﻗﺗراح ﺗﻘﻧﯾﺎت ﻣﺛل اﻟﺗﻧوﯾ م اﻟﻣﻐﻧﺎطﯾﺳﻲ ﻛطرق ﻟﻣﺳ...

تبدأ المسرحية م...

تبدأ المسرحية مع حوار رودريغو وياغو وتحريض ياغو لرودريغو أن يذهب إلى منزل برابانتيو ويخبره أن ابنته ...

ينظر دائما لليا...

ينظر دائما للياقة البدنية كهدف أساسى ، للتربية البدنية ، إلا أن خلال السنوات ، قد تغير جوهرياً تعريف...

تعرف مصادر المع...

تعرف مصادر المعلومات الإلكترونية في دليل فهرسة المصادر الإلكترونية 2AACR2 المعدل بأنها "مادة (بيانات...

•امتدد تطبيق قا...

•امتدد تطبيق قانون العقوبات خارج إقليم الدولة: • وهي في حالة توافر أحد المبادئ الآتية: • مبدأ عينية ...

ج: يستغل دعاة ا...

ج: يستغل دعاة الإلحاد القوامة، هذا الحق الشرعي الفطري الثابت في تأليب النساء، وحثهن على التمرد، وهذا...

نظرية المعرفة؛ ...

نظرية المعرفة؛ مكانتها وأهميتها في الفكرين الفلسفي والصوفي Andi Muhammad Ridwan1, Islamul Haq2 Unive...

ﺗﺣﻔﯾز اﻷﻋﺻﺎب اﻟ...

ﺗﺣﻔﯾز اﻷﻋﺻﺎب اﻟﻛﮭرﺑﺎﺋﻲ ﻋﺑر اﻟﺟﻠد. ﺗﺣﺗوي ﺑﻌض اﻟﻣﺳﺗﺷﻔﯾﺎت ﻋﻠﻰ آﻻتTENS .إذا ﻟم ﯾﻛن اﻷﻣر ﻛذﻟك، ﯾﻣﻛﻧك اﺳﺗﺋ...

Rapidité de la ...

Rapidité de la construction: *Boom démographique (1840/4470 1890/1099850 1900/1698575) *Ravage de la...

الحرب الباردة ه...

الحرب الباردة هي فترة من التوتر السياسي والعسكري بين الولايات المتحدة والاتحاد السوفيتي وحلفائهما، و...

عندما يحاول شخص...

عندما يحاول شخص ما قراءة جهاز العرض، فهو يحاول فقط القيام بذلك حسب توقعاته واهتماماته وميوله النفسية...