3.Change the manual regulation ratio in software to 1.9V and start recording the time using the timer.V.3 71 ENGINEERING TECHNOLOGY DEPARTMENT V.3 72 a. Go to your computer, open Gunt software, and switch to the "RT 634 Pressure Control Demonstration Unit" mode by clicking the arrows in the dialogue box as shown in Figure 6.4 (a). b. Click on "Charts" button as shown in Figure 6.4 (b).c. Set the "Software Controller" to "Manual" as shown in Figure 6.4 (c). d. In the "Manual Regulation Ratio" box, the maximum and minimum values that can be fed are 0V to 10V which corresponds to the 0% to 100% opening of electrical proportional valve (9) as shown in Figure 6.4 (d).For this purpose, a step in control value is applied to the system in the non-regulated mode and the system's response observed.Fully close the extraction valve (8) by turning it clockwise and then open it less than 1/4th by turning the knob 25 degrees in counter clockwise direction.Figure 6.4 Gunt Software Interface with steps 7.Ask instructor to check.Procedure 3.1.1.2.3.4.5.6.8.9.
Original text
- Procedure
3.1. Step Response of the System
This experiment is intended to ascertain the properties and response of the control system underlying
the model. For this purpose, a step in control value is applied to the system in the non-regulated mode
and the system’s response observed. The procedure as following. - Make sure the apparatus has a compressor connected to it via a hose and the equipment is ready to
use. Ask instructor to check. - Turn on the demonstration model via its main switch (10).
- Turn on the compressor and wait until the pressure level in gauge 7b reaches somewhere between 5
and 6 bar. - Make sure the throttle valve (3) is fully open.
- Fully close the extraction valve (8) by turning it clockwise and then open it less than 1/4th by turning
the knob 25 degrees in counter clockwise direction. - Prepare a stopwatch or open a stopwatch app on your phone for time calculations, then follow these
steps.
V.3 71
ENGINEERING TECHNOLOGY DEPARTMENT
V.3 72
a. Go to your computer, open Gunt software, and switch to the “RT 634 Pressure Control
Demonstration Unit” mode by clicking the arrows in the dialogue box as shown in Figure 6.4 (a).
b. Click on “Charts” button as shown in Figure 6.4 (b).
c. Set the “Software Controller” to “Manual” as shown in Figure 6.4 (c).
d. In the “Manual Regulation Ratio” box, the maximum and minimum values that can be fed are 0V
to 10V which corresponds to the 0% to 100% opening of electrical proportional valve (9) as shown
in Figure 6.4 (d).
Figure 6.4 Gunt Software Interface with steps - Using the software, start data sampling at 2 seconds interval and update the file name. Never delete
the old files, always start new section. (Refer to Appendix: Automatic Data Logging). - Change the manual regulation ratio in software to 1.9V and start recording the time using the timer.
- Monitor the pressure in tanks by means of the two pressure gauges (2 and 5). After a certain time,
the pressure assumes a constant value. Stop the timer, take pictures of the gauges for your report,
and fill the table below.
Summarize English and Arabic text online
Summarize text automatically
Summarize English and Arabic text using the statistical algorithm and sorting sentences based on its importance
Download Summary
You can download the summary result with one of any available formats such as PDF,DOCX and TXT
Permanent URL
ٌYou can share the summary link easily, we keep the summary on the website for future reference,except for private summaries.
Other Features
We are working on adding new features to make summarization more easy and accurate
Latest summaries
اتبعت الباحثة منهج البحث التجريبي في تحقيق هدف البحث, إذ يعد أحدث أنواع البحوث في التربية, وأكثرها د...
انطلقت في جامعة...انطلقت في جامعة عدن صباح اليوم الأحد 16 أغسطس، أعمال برنامج بناء الخطة الاستراتيجية والتشغيلية وتطوي...
المشكلة التي تو...المشكلة التي تواجه الطلبة والخريجين تتمثل المشكلة الأساسية في وجود فجوة بين التعليم الجامعي ومتطلبا...
أن أهمية هذه ال...أن أهمية هذه الموضوع تكمن في أن اغلب التشريعات ومنها قانون العمل الاردني قد أغفلت تنظيم قواعد وأحكام...
حُكم على عبد ال...حُكم على عبد البلوط (21 عامًا)، الإرهابي المنتمي لتنظيم الدولة الإسلامية، بالسجن لمدة 22 شهرًا في أي...
عزيزي الرجل الب...عزيزي الرجل البطل: اركان البروبوغاندا لأيديولوجيا الفيمنست -النسويات : بعد متابعة المنصات الأعلام...
تكدست أكوام الن...تكدست أكوام النفايات في عاصمة المهرة الغيضة، وذلك عقب اعتداء قام به مسلحون، باقتيادهم شاحنة تابعة لص...
الميثاق نيوز/ ا...الميثاق نيوز/ الجراحي/ الحديدة، متابعة خاصة، لم تعد شوارع مدينة الجراحي التابعة لمحافظة الحديدة تعج ...
التفاعل النشط :...التفاعل النشط : هي استراتيجية تقوم على تطبيق أنشطة تشاركية تفاعلية داخل الصف الافتراضي بهدف تحفيز ال...
**1. مفهوم البد...**1. مفهوم البدل وحكمه الإعرابي** * **البدل** هو أحد التوابع الأربعة (النعت، المضاف إليه، المعطوف، ...
تفاقمت معاناة ا...تفاقمت معاناة المواطنين في العاصمة المؤقتة عدن اليوم الجمعة مع ظهور أزمة مواصلات حادة تضاف إلى سلسلة...
Dr. Amar Babiki...Dr. Amar Babikir Elhussein BSc, MSc & PhD Biosynthesis of Nonessential Amino acids and Fate of Amin...